Popular Products

-
SPECIFICATION
-
TECHNICAL SPECIFICATIONS
-
RESOURCES
-
SHIPPING
-
REVIEW
This device is capable of accurately measuring the temperature of liquids and vapors, as well as the surface temperature of solid objects. Its range of measurement is much broader than traditional mercury thermometers and alcoholometers. It is ideal for use in high-temperature environments such as blast furnaces and cooking, as well as for measuring extremely low temperatures such as liquefied hydrogen and nitrogen.
FEATURE
- High accuracy
- Convenient operation.
- Unit Celsius and Fahrenheit unit.
- Data hold and MAX、MIN、AVG
- Human centered design, easy operation.
- Double display with backlight shows T1/T2 and combination of T1 and T2.
- To measure the thermocouple of J,K, T,E,N and R type.
- The electrical compensation function provide the compensation to the thermocouple error so as to improve the overall precision.
SPECIFICATION
Main unit |
|
Measuring range |
J-type:-210℃ to 1200℃(-346℉ to 2192℉) K-type:-200℃ to 1372℃(-328℉ to 2501℉) T-type:-250℃ to 400℃(-418℉ to 752℉) E-type:-150℃ to 1000℃(-238℉ to 1832℉) N-type:-200℃ to 1300℃(-328℉ to 2372℉) R-and S-type:0℃ to 1767℃(32℉ to 3212℉) |
Resolution |
0.1t <1000°;1.0t ≥1000° |
Accuracy |
±0.1%+0.6℃ |
input |
Bouble channel input |
Operating Temperature |
0°C ~ 40 °C |
Storage Temperature |
- 10 °C ~ 50 °C |
Storage Humidity |
20~90% |
Power supply |
3*1.5V AAA Battery |
Size |
72*29*145.5mm |
Weight |
159.0g |
K-type thermocouple(2 pieces attached) |
|
Measuring range |
0~250℃ (300℃ in short time) |
Error allowed |
2.5℃ or 0.75%,Class II |
Heat response time |
The < 10 seconds |
We are dedicatedly involved in providing an excellent quality array of Labart Measuring Instrument
Measuring Range (Main Unit) |
J-type: -210°C to 1200°C (-346°F to 2192°F) K-type: -200°C to 1372°C (-328°F to 2501°F) T-type: -250°C to 400°C (-418°F to 752°F) E-type: -150°C to 1000°C (-238°F to 1832°F) N-type: -200°C to 1300°C (-328°F to 2372°F) R-and S-type: 0°C to 1767°C (32°F to 3212°F) |
Resolution | 0.1°C < 1000°; 1.0°C ≥ 1000° |
Accuracy | ±0.1% + 0.6°C |
Input | Double channel input |
Operating Temperature | 0°C ~ 40°C |
Storage Temperature | -10°C ~ 50°C |
Storage Humidity | 20% ~ 90% |
Power Supply | 3 × 1.5V AAA Batteries |
Size | 72 × 29 × 145.5 mm |
Weight | 159.0 g |
K-type Thermocouple | 2 pieces attached |
Measuring Range (K-type Thermocouple) | 0°C ~ 250°C (300°C for short time) |
Error Allowed (K-type) | ±2.5°C or 0.75%, Class II |
Heat Response Time (K-type) | Less than 10 seconds |
For orders placed before 4PM IST, we endeavour to process the same business day. Orders placed after 4PM IST will be processed the next business day.
During sale events and new collection launches, there may be a slighly longer processing time.